Pre-Analytical Errors in Nigerian Laboratories

· 4 min read · By the OctoQore team

Wrong tube, missing name, illegible request, lost sample. Where errors enter a Nigerian laboratory before testing starts, and the checks that catch them.

Owners spend money on analysers and reagents, because that is where the result is made. But a published study of laboratory request forms in an African laboratory notes that most laboratory errors, in the range of 50% to 70% across the literature it cites, happen before the test: in the request, the collection, the labelling and the transport. Errors in the analytical stage itself average under 10% in the same review.

Your best analyser cannot fix a specimen from the wrong patient.

Where errors enter

The same study lists the most frequent causes of errors before analysis. In plain terms, these are the places to look in your own laboratory.

1. The request itself. A form that is incomplete, illegible or missing a test. Nigerian studies of request forms found many were filled in inadequately, with missing clinical details and unreadable writing.

2. The wrong or missing identification. A tube with no name, a name that does not match the form, or two patients with similar names on the same day.

3. The wrong tube or container. The right test in the wrong container, or not enough specimen.

4. Damaged specimens. Haemolysed or clotted samples that cannot be tested properly.

5. The wrong time or condition of collection. A fasting test taken from a patient who ate, or a sample left too long before it was delivered.

6. Lost samples. A tube sent with a driver, or from a collection point, that never arrives, or arrives with no record of who carried it.

7. Unrecorded rejections. The bench throws out a bad specimen, the patient is called, and no one writes down why. The same mistake happens again next week.

Controls that catch them

None of these need expensive equipment. They need a rule and a record.

Check two identifiers, every time. Before collection, the collector confirms the patient's name and one more identifier against the order. After collection, the label is made and checked in front of the patient, not later at the bench.

Label at the point of collection. A tube labelled in the corridor, or at the end of a round, is where mix-ups happen.

Record who collected, when and where. If a result is questioned, you must be able to say who took the sample and when.

Record every handover. From collector to courier to receiving, each person signs for it. The most common place a sample vanishes is the gap between two people with no record.

Check at receiving, not only at the bench. Receiving should compare the tube with the order, check the container and condition, and accept, reject or quarantine, with a reason in writing.

Count your rejections. Rejections are not failures to hide. They are the cheapest quality data you have. Count them by reason each week. If most are haemolysis from one collection point, you know where to train.

Redesign the request form. If the same field is left blank again and again, make it required, or remove it. The study behind this post recommends reviewing request forms, training clinical staff and reviewing rejection practice.

A quick self-check

Pick ten specimens at random from last week and try to answer for each: who collected it, when, who handled it next, who received it, and what condition it was in. If you can answer all five for all ten, your front end is in good shape. If not, the gaps you find are where errors enter.

How OctoQore helps

In OctoQore, specimens are collected from a To collect queue. The collector scans the tube and photographs the specimen, and the system records who collected it and when. Each handover is recorded, so the specimen carries a trail. At receiving, the specimen is accepted, rejected or quarantined, with a reason. Lab Overview shows the count of rejected specimens and the reasons recorded, for the dates you choose.

OctoQore does not decide whether a specimen is acceptable. Your staff do, and the system keeps the record. Read about how OctoQore tracks specimens, or see how to choose a laboratory information system.

Source: a study of laboratory request forms and pre-analytical errors published in the African Journal of Laboratory Medicine, and Nigerian studies on request form completion cited in it.

Keep reading

running the lab

Lab Referral Fees and Rules in Nigeria

Doctors and facilities send patients to laboratories and money often follows. What Nigeria's professional rules say and how to keep clean referral records.

· 4 min read

running the lab

When Will My Result Be Ready? Lab Turnaround Time

Patients ask when results will be ready and most front desks guess. How to measure turnaround honestly, promise times you can keep and see late work early.

· 4 min read